HOME
HOME HOME HOME HOME HOME
HOME
HOME HOME HOME HOME HOME
HOME
PRODUCTS SERVICES PROFILE CONTACTS HOME

TTS2+
TTS2+
DIGITAL
RECORDER
SYSTEM2
TTS2
DIGITAL
RECORDER
TTS2+
TAP TL3
DIGITAL
RECORDER
     

TTS SC2008 Source Controller

Introducing the TTS-SC2008 Source controller from T.T. Surveys.

Based on the existing SC2000, the SC2008 introduces even more features and power into the same size package.

SC2008
The SC2008 is made up of a Source Control Units (SCU)and a  compact Industrial PC or Ruggedised Laptop. The SCU is highly integrated with several embedded Micro- controllers. It is capable of controlling up to 8 Sleeve Guns and up to 4 dual solenoid GI Guns in its standard configuration. .

Toggle mode is available, doubling the time between gun maintenance and enabling faster firing without compressor upgrades.

The PC contains only standard hardware, and runs under Windows NTİ or XP-PROİ. It operates as a GUI and data logger.

The SC2000 has powerful QC features with dynamic and historical analysis available graphically every shot. Auto calibration is used to provide QC benchmarks.

Comprehensive logging facilities are also included. The logging file is stored on disk in a standard text format and can be loaded into a Word Processor or Spreadsheet for further analysis.

Safety is addressed by using failsafe disarm software plus a Master Manual Safety Switch override.

Performance parameters can be output as an ASCII String, each shot via a serial port. This is useful for interfacing to external equipment. The TTS2+ recording system supports this QC output and can display this information in the Recorder line log.

TOP OF PAGE


SC2008 Key Features include:

  • Compact design - Basic 8 Gun configuration occupies only 4U-rack space.

  • Detect Signal DisplayNo separate desktop PC required.

  • Alternate gun firing in toggle mode.

  • Supports TI-Sleeve and GI types of gun.

  • Internal test modes for ease of Gun testing.

  • 50/100us average timing accuracy.

  • Easily expandable in units of four or eight guns

  • Variable solenoid output voltage. 50-70V range.

  • Software controlled solenoid output pulse width.

  • Selectable trigger input polarity

  • Historical QC DisplayTTL Timebreak output set at Aimpoint.

  • Programmable detector gain and polarity.

  • 10bit ADC resolution for sensor detection.

  • Real time graphical display of Detect sensor data with zoom options.

  • Peak pulse and zero-crossing Detect modes.

  • Multiple threshold settings and error criteria for amplitude and timing.

  • All QC settings are stored on disk so changes are not lost.

  • Historical QC data. Graphs of amplitude and timing error as well as timing error distribution are available on line.

  • Online LoggingComprehensive logging options with user selectable Line details.

  • Logging files are written to disk and can be edited or printed later.

  • ASCII serial logging string output every shot via PC serial port.





TOP OF PAGE